Send Message
Home > products > IGBT Power Module > STK621-033N-E Mosfet Power Module Hybrid Inverter Circuit SIP Full Molded

STK621-033N-E Mosfet Power Module Hybrid Inverter Circuit SIP Full Molded

manufacturer:
ON Semi / Catalyst Semi
Description:
Half Bridge (3) Driver AC Motors IGBT 23-SIP
Category:
IGBT Power Module
Price:
Negotiate
Payment Method:
T/T, Western Union,Paypal
Specifications
Features1:
Very Low DCR; Excellent Current Handling
Features2:
Miniature 3.0 × 3.0 Mm Footprint; Less Than 1.5 Mm Tall
Features3:
RoHS Compliant Silver-palladium-platinum-glass Frit. Other Terminations Available At Additional Cost.
Weight:
T 40 – 45 Mg
Ambient Temperature:
E –40°C To +85°C With Irms Current, +85°C To +125°C With Derated Current
Storage Temperature:
Component: –40°C To +125°C. Packaging: –40°C To +80°C
Highlight:

thyristor diode module

,

hybrid inverter circuit

Introduction

STK621-220A Mosfet Power Module Hybrid Inverter Circuit SIP Full Molded

 

 

STK621-220A INVERTER POWER HYBRID MODULE

SIP Full Molded Package

 

Overview

This IC is a 3-phase inverter power hybrid IC containing power elements (IGBT and FRD), pre-driver, overcurrent and excessive temperature protection circuit.

 

Application

• 3-phase inverter motor drive

 

Features

• Integrates power elements (IGBT and FRD), pre-driver, and protective circuit.

• Protective circuits including overcurrent (bus line), excessive temperature and pre-drive low voltage protection are built in.

• Direct input of CMOS level control signals without an insulating circuit (photocoupler, etc) is possible.

• Single power supply drive is possible by using a bootstrap circuit with a built-in IC

• Temperature monitor is possible by the thermistor inside the IC

• Built-in simultaneous upper/lower ON prevention circuit to prevent arm shorting through simultaneous ON input for the upper and lower side transistors. (Dead time is required for preventing shorting due to switching delay.)

• SIP (The single in-line package) of the transfer full mold structure.

 

Specifications Absolute

Maximum Ratings at Tc = 25°C

 

Parameter Symbol Condition Ratings Unit
Supply voltage Vcc + - −, surge < 500V 450 V
Collector-emitter voltage Vce + - U (V, W) or U (V, W) 600 V
Output current Io +, −, U, V, W terminal current ±30 A
Output peak current Lop +, −, U, V, W terminal current PW = 100μs ±45 A
Pre-driver supply voltage VD1,2,3,4 VB1 - U, VB2 - V, VB3 - W, VDD - VSS 20 V
Input signal voltage Vin HIN1, 2, 3, LIN1, 2, 3 terminal 0 to 7 V
FAULT terminal voltage VFAULT FAULT terminal 20 V
Maximum loss Pd Per 1 channel 49 W
Junction temperature Tj IGBT, FRD junction temperature 150 °C
Storage temperature Tstg   -40 to +125  °C
Operating temperature Tc H-IC case temperature -20 to +100 °C
Tightening torque   A screw part at use M4 type screw 1.17 N-m
Withstand voltage  Vis 50Hz sine wave AC 1 minute 2000 VRMs

In the case without the instruction, the voltage standard is - terminal = VSS terminal voltage. *1 Surge voltage developed by the switching operation due to the wiring inductance between the + and –terminals. *2 VD1 = between VB1-U, VD2 = VB2-V, VD3 = VB3-W, VB4 = VDD-VSS, terminal voltage. *3 Flatness of the heat-sink should be lower than 0.25mm. *4 The test condition is AC 2500V, 1 second.

 

 

Notes

1. Input ON voltage indicates a value to turn on output stage IGBT. Input OFF voltage indicates a value to turn off output stage IGBT. At the time of output ON, set the input signal voltage 0V to VIH (MAX). At the time of output OFF, set the input signal voltage VIL (MIN) to 5V.

2. When the internal protection circuit operates, there is a Fault signal ON (When the Fault terminal is low level, Fault signal is ON state : output form is open DRAIN) but the Fault signal doesn't latch. After protection operation ends, it returns automatically within about 18ms to 80ms and resumes operation beginning condition. So, after Fault signal detection, set OFF (HIGH) to all input signals at once. However, the operation of pre-drive power supply low voltage protection (UVLO: it has a hysteresis about 0.3V) is as follows. Upper side → There is no Fault signal output, but it does a corresponding gate signal OFF. Incidentally, it returns to the regular operation when recovering to the normal voltage, but the latch continues among input signal ON (LOW). Lower side → It outputs Fault signal with gate signal OFF. However, it is different from the protection operation of upper side, it is automatically resets about 18ms to 80ms later and resumes operation beginning condition when recovering to normal voltage. (The protection operation doesn't latch by the input signal.)

3. When assembling the hybrid IC on the heat sink with M4 type screw, tightening torque range is 0.79N•m to 1.17N•m. Flatness of the heat-sink should be lower than 0.25mm.

4. The pre-drive low voltage protection is the feature to protect a device when the pre-driver supply voltage declines with the operating malfunction. As for the pre-driver supply voltage decline in case of operation beginning, and so on, we request confirmation in the set.

 

 

Send RFQ
Stock:
MOQ:
5pcs